Irrigation Water Quality for Commercial Growers: Testing, Treatment & Fertigation

NPK Industries irrigation water quality guide for commercial growers, featuring pH and EC testing, water chemistry, filtration, fertigation equipment and greenhouse crops.

Water quality is a measurable production input—not simply the water coming out of the hose. The dissolved minerals, alkalinity, sodium, chloride, nutrients, suspended solids, and potential contaminants entering a commercial irrigation system can affect fertilizer formulation, root-zone conditions, equipment reliability, operating cost, and crop performance. That matters whether you grow greenhouse tomatoes, lettuce, herbs, ornamentals, nursery starts, berries, or field crops.

There is no single “perfect water” number for every grower. A water source can be perfectly acceptable for one crop and management system yet require treatment or a different nutrient strategy in another. The right approach begins with representative testing, then matches the results to the crop, growing medium, irrigation method, and fertilizer program. This article walks through that decision process with practical tables, examples, and research you can verify.

Commercial grower quick answer

Test source-water pH, alkalinity, EC, hardness, calcium, magnesium, sodium, chloride, and boron at minimum; expand the panel to include bicarbonate/carbonate, nitrogen species, potassium, sulfate, iron, manganese, and other relevant elements. Interpret those numbers together, account for what your water already contributes, and confirm the chemistry after treatment and fertilizer injection. Do not choose an acid dose, Cal-Mag addition, or RO system from pH or EC alone.

On mobile, scroll reference tables horizontally to see all columns.

Why irrigation water quality matters for yield, consistency, and cost

Water enters the fertility program before any fertilizer is added. Dissolved calcium, magnesium, nitrate, sulfate, and other ions may contribute to a crop's nutrient supply; bicarbonate alkalinity can influence substrate pH over repeated irrigations; sodium and chloride can accumulate; and sediment, iron deposits, or microbial growth can interfere with emitters and filters. A grower who treats incoming water as chemically empty may spend money correcting a problem that began at the source.

In commercial production, even small recurring errors scale. A reservoir drift repeated across zones or a partially clogged injector may affect thousands of plants before leaves show obvious symptoms. The goal is not an impressive-looking water test; it is a repeatable system for interpreting the test, making defensible decisions, and verifying delivered irrigation.

For the larger relationship among water, fertilizer, and root-zone conditions, read Essential Inputs for Commercial Crop Production.

1. Know your source—but never assume its chemistry

Municipal, well, surface, rain-harvested, reclaimed, and reverse-osmosis water are source or treatment descriptions, not reliable nutrient recipes. Two nearby wells can differ substantially; a city may change source blends; rainwater can accumulate contamination in storage; and RO water can change with membrane performance or intentional blending.

Water source What to investigate Best starting evidence
Municipal / city Source blending, disinfectant residual, alkalinity, sodium, calcium and magnesium; building treatment may change tap chemistry Current utility chemistry report plus sample at the actual irrigation point
Private well / spring Site-specific minerals, alkalinity, sodium, chloride, nitrate, boron, iron and manganese Comprehensive irrigation-water laboratory panel
Pond / canal / river Sediment, algae, biological exposure, runoff influences, and seasonal variation Source-water panel plus sampling across seasons and any relevant biological testing
Harvested rainwater Collection-surface contamination, storage hygiene, low buffering capacity, possible dissolved ions after storage Sample after storage and any treatment
RO / blended / reclaimed Actual output chemistry, membrane or treatment performance, microbiological suitability, blending variability Post-treatment or blended-water analysis, not nominal equipment specifications

City-water reports are a useful starting point, not a substitute for testing the water actually reaching the crop. U.S. community water systems issue annual Consumer Confidence Reports, but these drinking-water summaries may not contain all the alkalinity, hardness, and nutrient information a commercial grower needs. See the EPA guide to Consumer Confidence Reports.

Likewise, irrigation suitability is not proof that a source is safe to drink. Private-well drinking-water assessment is a separate public-health task; use the CDC's well-water testing guidance for that purpose.

2. What should commercial growers test in irrigation water?

Before opening a greenhouse, switching wells, changing treatment equipment, or reformulating nutrients, obtain a laboratory analysis of the actual source or point-of-use water. For a large facility, sample both before and after major treatment steps. The test panel should cover individual ions rather than reporting only pH and TDS. Oregon State University and Penn State Extension identify core chemical parameters and explain why interpretation must consider cropping system and local conditions (OSU irrigation-water guidance; Penn State irrigation-test interpretation).

Test Why it matters How to use it
pH Current acid/base condition Interpret with alkalinity; compare raw, treated, and delivered water
Total alkalinity (often mg/L as CaCO3) Acid-neutralizing capacity and long-term effect on substrate pH Assess need for treatment or fertilizer-strategy changes
EC (mS/cm or µS/cm) Combined dissolved-ion load Track source variability and salt burden, not individual nutrients
Hardness + calcium + magnesium Potential nutrient inputs and scaling Credit measured ions appropriately; evaluate precipitation risk
Sodium + chloride Potential ion accumulation and crop sensitivity Review crop, soil/substrate, drainage and reuse practices
Boron and relevant trace elements Crop-dependent toxicity risks Request crop-specific interpretation; do not use blanket thresholds
Bicarbonate/carbonate, sulfate Buffering and potential chemical interactions Review alongside alkalinity, calcium, and treatment design
Nitrate-N, ammonium-N, potassium, phosphorus Nutrients already delivered by irrigation Account for contributions using the correct reported nutrient basis
Iron, manganese, suspended solids/turbidity Staining, solids, and emitter or filtration issues Investigate deposits and specify treatment from laboratory evidence
Biological or chemical contaminants as indicated Crop, worker, produce, or system-specific exposure concerns Order targeted testing appropriate to source, intended use, and applicable standards

How to collect a representative water sample

  1. Record source, sample location, date, recent weather or treatment changes, and equipment upstream of the sampling point.
  2. For source-water chemistry, collect before fertilizer or acid injection. For delivered fertigation, take a separate downstream sample after proper mixing.
  3. Use the laboratory's container, preservation, and shipping instructions. Some analytes and biological tests have special handling requirements.
  4. Label raw, treated, blended, reservoir, and drain samples separately. Do not compare them as if they were the same type.
  5. Repeat testing after source or treatment changes and at a frequency justified by seasonality, crop value, and system risk.

3. Irrigation water pH versus alkalinity: the distinction that changes decisions

pH measures the water's present acid/base condition. Alkalinity measures its capacity to neutralize acid. These numbers are related, but they are not interchangeable. A high-pH sample may have modest alkalinity; another source at the same pH may contain substantially more bicarbonate and require a very different treatment approach.

High alkalinity can drive substrate pH upward under repeated irrigation, depending on the medium, fertilizer acidity, crop uptake, and water volume. Very low alkalinity may leave a solution poorly buffered against pH shifts. Penn State's greenhouse guidance discusses approximately 30–100 mg/L as CaCO3 as a useful management reference for many operations—not a universal target for every crop or production system (source and limitations).

Example: two water sources with the same pH

Illustrative sample Measured source pH Measured alkalinity What the grower should conclude
Source A 7.8 40 mg/L as CaCO3 The pH reading alone does not establish a major buffering burden
Source B 7.8 220 mg/L as CaCO3 The higher alkalinity may have a much larger effect on media-pH trends and acid demand

These figures are hypothetical teaching examples, not real customer results or acid prescriptions. Do not infer a precise acid injection rate from this comparison. Acid choice, purity, endpoint, injector compatibility, and safety requirements must be verified by qualified personnel. Never combine acid with chlorine-based disinfectants or incompatible chemicals.

Hardness is different again. It largely reflects calcium and magnesium, usually reported as calcium-carbonate equivalents. Hardness alone does not reveal elemental calcium content, the Ca:Mg ratio, or alkalinity. Treating all “hard water” as bad can throw away nutrients the crop could otherwise use.

Related reading: Plant Nutrient Lockout: Causes, Diagnosis and Prevention explains why pH, salts, and root function must be evaluated together.

4. EC, TDS, salinity, sodium and chloride: five terms that are easy to confuse

Electrical conductivity (EC) measures how well an aqueous solution conducts electricity; for irrigation, it serves as an aggregate indicator of dissolved ions. It does not identify whether those ions are useful calcium and magnesium, fertilizer nutrients, or potentially problematic sodium and chloride. That is why two water samples with the same EC can behave differently in a crop.

  • EC units: 1.0 mS/cm = 1,000 µS/cm = 1.0 dS/m. Check which unit your meter or lab uses before comparing results.
  • TDS / ppm displays: many handheld meters estimate TDS from conductivity using a device-specific conversion. Do not treat the displayed “ppm” as a laboratory analysis of individual nutrients.
  • Raw-water EC: tells you the baseline dissolved-ion load before fertilizer is added.
  • Fertigation EC: tracks the delivered solution when the baseline water, formulation, and calibration are known; it cannot verify each nutrient concentration.
  • Root-zone EC: reflects the extraction or sampling method and growing environment. Reservoir EC and root-zone EC are not interchangeable.

For soil-based production, high salt concentrations can make water harder for roots to extract even when soil appears moist. Excess sodium can also damage the structure and infiltration of susceptible mineral soils. The sodium adsorption ratio (SAR) evaluates sodium relative to calcium and magnesium; its significance depends on salinity, soil properties, irrigation, and drainage. In containers and recirculating hydroponics, risk often centers on ion accumulation and plant sensitivity rather than the same field-soil structural mechanism (Oklahoma State irrigation test interpretation).

Boron deserves individual attention because crops need only small quantities and tolerances differ. If a lab flags boron, sodium, or chloride, investigate the actual concentration and crop-specific susceptibility before choosing a treatment.

See also Nutrient Toxicity in Plants: Diagnose Excess Nutrients and Salt Stress.

5. Count the nutrients already present in your irrigation water

A comprehensive lab report can show that your water supplies part of the calcium, magnesium, nitrate-nitrogen, sulfate, or other nutrients delivered during irrigation. These contributions may justify an adjustment to a verified crop nutrient target, but they do not automatically prove that a supplement is unnecessary.

When water contributes calcium or magnesium, review its individual concentrations rather than relying on a general “hardness” number. When a report shows nitrate, pay attention to the reporting basis: nitrate-N (NO3-N) is not numerically the same as nitrate ion (NO3). Use compatible units before making nutrient credits.

Simple nutrient-delivery calculation

Element delivered (grams) = concentration (mg/L) × irrigation volume (L) ÷ 1,000.

For example, water containing 25 mg/L of elemental calcium applied at 10,000 L delivers 250 g of calcium in that irrigation volume. This is a mass delivered to the production system, not a claim that roots absorb all 250 g. Actual availability depends on soil or substrate chemistry, leaching, precipitation, and crop demand.

Use measured source-water concentrations with an appropriate, crop-specific fertilizer target—not guessed concentrations based on “well water” or “city water.”

Where water analysis meets KALIX nutrition

Once the source-water contribution and crop target are known, commercial nutrient programs may need measured adjustments. NPK Industries carries KALIX Calcium, KALIX Magnesium Sulfate, and KALIX Cal Mag. These are product options to evaluate against the actual water analysis and complete fertilizer formula—not default fixes for every water problem. Adding nutrients without testing can worsen an imbalance or increase solution EC unnecessarily.

6. Choose water treatment according to the measured problem

Installing treatment equipment before knowing the water problem can create new costs and even new chemistry. A sediment filter does not remove dissolved sodium. A conventional sodium-exchange softener lowers calcium/magnesium hardness but can increase sodium. A reverse-osmosis membrane can substantially reduce many dissolved ions, but treated-water composition depends on feed chemistry, membrane condition, blending and operation.

Treatment Best-suited concern Important limitation or verification
Sediment screening / filtration Suspended particles and physical clogging Does not remove dissolved salts, alkalinity, or most dissolved ions
Iron / manganese treatment and filtration Confirmed iron or manganese precipitation or staining Proper treatment sequence depends on speciation, oxygenation, pH and equipment
Activated carbon Selected organic compounds or disinfectant residuals where equipment is rated accordingly Not a substitute for dissolved-salt removal or complete microbial control; verify capacity and contact time
Reverse osmosis (RO) Reduction of many dissolved salts where justified Monitor permeate, recovery, pre-treatment, membrane maintenance and concentrate disposal
Source-water blending Reducing a measured constituent using a lower-concentration source Requires analyses of both sources and monitoring of the blended output
Alkalinity correction / acid injection Measured excessive buffering for a specific growing system Needs verified water analysis, equipment, dosing plan, chemical compatibility and trained operators
UV or other engineered disinfection Specific microbial-management objectives in an engineered system Performance depends on water clarity, exposure, validated equipment and target organism; no blanket crop-health guarantee
Conventional ion-exchange softening Hardness reduction for equipment in suitable applications Sodium-based units may increase sodium in irrigation water; check bypass options and post-treatment chemistry

Use a before/after sample to confirm whether the treatment actually solved the measured problem. A sophisticated treatment skid is not a substitute for verifying the water leaving it. Be especially cautious with chemical cleaning or antimicrobial products: use only according to their current labels and the system manufacturer's compatibility requirements. Cleaning a line, managing precipitates, and controlling a plant pathogen are different technical and regulatory objectives.

7. Fertigation starts with source water, not the injector dial

When irrigation water enters a fertigation system, the final delivery depends on three things: the incoming water, the fertilizer stock concentration, and the actual injector performance. Assuming an injector set to 1:100 is delivering exactly that ratio can produce systematic errors across a commercial crop.

Build a dependable mixing and verification sequence

  1. Know your incoming water. Record raw or treated source EC, pH, alkalinity, and relevant ions.
  2. Use a verified formulation. Choose crop-specific final nutrient targets and ingredient analyses; account for source-water nutrient contributions.
  3. Check stock solubility and compatibility. As a general rule, keep concentrated calcium-containing stocks separate from phosphate- or sulfate-containing concentrates unless compatibility has been established.
  4. Calibrate the injector. Verify the actual intake/delivery ratio using manufacturer-approved procedures; assess pressure, flow, and suction strainers.
  5. Measure after mixing. Sample delivered solution downstream at a representative outlet. Compare source EC and fertilizer-solution EC, but recognize that EC alone cannot identify which ingredient is wrong.
  6. Observe the root zone. Review crop response, media/substrate pH and EC using a suitable sampling method, and any solution accumulation over time.

University of Georgia Cooperative Extension's injector guide details selection, maintenance, and calibration; Penn State's hydroponic nutrient-program guidance explains stock compatibility and solubility. See NPK's stock-tank precipitation and fertigation compatibility guide and stock concentrate mixing resource for complementary information.

Operational warning: Chemical precipitation, injector failure, and clogged emitters can look like a fertilizer deficiency at the plant level. Verify delivered flow and solution chemistry before increasing fertilizer concentration.

8. Interpret the same water differently in soil, coco, rockwool and recirculating hydroponics

Growing system What changes the interpretation Monitoring emphasis
Field soil Soil texture, drainage, rainfall, sodium hazard, cumulative salts Irrigation water plus appropriate soil salinity and sodium measurements
Greenhouse soil / raised beds Managed irrigation and fertilizer accumulation with less rainfall leaching Root-zone pH, salinity trends and infiltration
Peat/bark/container media Small root volume, lime charge, fertilizer acidity, leaching and substrate buffering Media-specific pH and EC test method, incoming alkalinity
Coco / rockwool / soilless slabs Fertigation frequency, substrate properties, drain and salt accumulation Source vs feed vs drain solution; substrate-specific extraction
NFT / DWC / recirculating hydroponics Changes in individual-ion balance, evaporation, repeated reuse and system hygiene Reservoir and return EC/pH/temp, water additions, periodic ion-specific analysis

The same meter reading does not mean the same biological condition across these systems. A peat-based transplant tray, rockwool slab, mineral field soil, and recirculating hydroponic tank cannot be interpreted with identical root-zone testing methods.

Read our commercial NFT guide and Sustainable Hydroponics for Commercial Crops for system-specific considerations.

9. Water recycling and runoff: measure efficiency rather than assume it

Recirculation can reduce fertilizer-rich discharge when it replaces a system that routinely discards drainage. But its economics and environmental performance depend on the actual operation: reuse volume, nutrient drift, salinity accumulation, filtration, biological risks, energy demand, and waste-stream handling.

A peer-reviewed review by Fathidarehnijeh and colleagues in the Canadian Journal of Plant Science explains why EC-only replenishment may miss individual-ion imbalances in hydroponics (research review, DOI 10.1139/cjps-2023-0034). Work on hydroponic arugula and basil also demonstrates that nutrient-replenishment strategy and species affect solution composition (Houston et al., 2023). A separate hydroponics paper illustrates an engineered near-zero-discharge approach in a specific experimental context—not a performance promise for all greenhouses (Langenfeld and Bugbee, 2024).

For a useful operating picture, track freshwater input, fertilizer added, solution reclaimed, solution disposed, harvest weight/quality, and maintenance costs. Keep disposal, crop food-safety requirements, and local discharge rules in scope. Never treat untreated recovered water as automatically safe for reuse.

10. Water-quality troubleshooting before you change the fertilizer

Observed problem Possible water/system contributors Best next verification
Substrate pH drifts upward Alkalinity, fertilizer acidity, irrigation volume, medium characteristics Source alkalinity + appropriate current media-pH test
White crust or plugged emitters Carbonate or fertilizer precipitation, hard-water scale, deposits Inspect deposits; test Ca, Mg, alkalinity, pH and stock compatibility
Orange/brown deposits or slime Iron-related oxidation or microbial activity among other causes Source iron and manganese; filter/deposit inspection; water-treatment review
Plants struggle despite normal feed EC Imbalanced individual ions, root-zone stress, inaccurate sensor or injector Verify meters, water-ion panel, fertilizer program and root-zone test
Salt symptoms or poor field-soil infiltration Total salinity, sodium accumulation or inadequate leaching Irrigation EC + Na/Ca/Mg; relevant soil EC and SAR assessment
Reservoir EC rises between top-ups Water loss and unequal ion uptake, possible concentration drift Log refill volume; compare reservoir and fresh-input chemistry
Sudden changes after installing treatment Softener sodium exchange, RO blending, dosing/filtration changes Compare raw and treated-water laboratory results
Uneven crop response by irrigation zone Hydraulic imbalance, clogging or uneven fertilizer delivery Measure actual zone flow/pressure and delivered solution at outlets

These are diagnostic possibilities, not diagnoses from appearance alone. If you are seeing chlorosis, necrosis, stunting or unusual roots, compare crop symptoms with measured conditions instead of assuming they identify one nutrient problem. Our plant nutrient deficiency guide can help organize the differential.

11. Build a practical commercial water-quality monitoring program

A useful monitoring program is consistent, documented, and tied to decisions. The exact frequency depends on source variability, treatment, crop sensitivity, facility size, and risk—not a universal calendar for every farm.

When Check Document
Before commissioning or changing source Full irrigation-water panel and treatment review Lab report, sample point, crop/system assumptions
At each nutrient-mixing or irrigation check as needed Calibrated pH and EC; temperature and level where relevant Source/feed/reservoir values, amendments, operator, corrective action
On a scheduled operating inspection Filters, injector performance, pressure/flow, deposits and leaks Zone anomalies, service history, equipment calibration
Periodically and after significant changes Lab chemistry at appropriate source/treatment points; selected ion analysis for recirculation Seasonal trends and whether treatment/formulation adjustments worked
When symptoms or equipment faults appear Targeted source/feed/root-zone sampling Hypotheses, tests performed, findings, and recheck date

A successful audit trail answers: What changed? What did we measure? What did we change? Did the change work? Document the point of measurement. Raw water, treated water, fertilizer feed, and drain solution are different samples with different meanings.

12. Turn water analysis into a more reliable commercial fertility program

Better water management often starts with a modest investment: a representative lab test, calibrated meters, and a clean record of the system. From there, you can decide whether the right move is no treatment, targeted treatment, blending, better injector calibration, or reformulating fertilizer.

For commercial operators evaluating water-soluble fertilizer supply, browse the KALIX Complete Plant Nutrition collection and review professional feed charts as product resources. Feed charts are starting references—not universal targets and not replacements for verified crop and water data.

Managing multiple zones, thousands of plants, or an unfamiliar water source?

Bring your irrigation-water test, crop and medium details, source-treatment information, and existing fertigation program to a commercial discussion. The goal is to build a measurable nutrient strategy rather than sell you a bag you may not need.

Explore KALIX commercial pricing and water-informed nutrient planning.

Frequently Asked Questions: Commercial Irrigation Water Quality

What water-quality tests do commercial growers need?

At minimum, start with pH, alkalinity, EC, hardness, calcium, magnesium, sodium, chloride and boron. A full irrigation-water panel adds other nutrients and trace elements; test for source-specific contamination where relevant. Sample the actual water reaching your irrigation system.

What is the best pH for irrigation water?

There is no single source-water pH value that guarantees good nutrition across crops and growing media. The appropriate delivered feed and root-zone pH depend on crop and system, while water alkalinity often governs how much source water affects substrate pH over time.

What is the difference between water pH and alkalinity?

pH describes current acidity/basicity. Alkalinity measures acid-neutralizing capacity. Two sources with the same pH can have very different alkalinity and very different treatment needs.

Is well water better or worse than city water for growing?

Neither is categorically better. The water source name does not establish calcium, magnesium, bicarbonate, sodium or contaminant concentrations. Test the actual source and review any treatment that occurs before irrigation.

Does high EC mean my irrigation water has plenty of nutrients?

No. EC measures combined conductivity, not the identity of dissolved ions. Sodium and chloride can raise EC without meeting the crop's nutritional needs.

Should every hydroponic grower use reverse osmosis?

No. RO is useful when a measured problem justifies removing dissolved ions, but it adds capital, maintenance and concentrate-disposal considerations. Assess the source first and measure the actual RO output.

Does hard water mean I should stop using calcium or Cal-Mag?

No. Hardness summarizes calcium-plus-magnesium behavior, not the crop's specific needs or the balance of those elements. Use measured elemental concentrations and a verified nutrient program before changing fertilizer.

Can I use water from a household sodium softener for irrigation?

It may be unsuitable for some crops or systems because conventional softeners commonly replace calcium and magnesium with sodium. Compare raw and softened-water analyses; an unsoftened bypass may be preferable if appropriately evaluated.

How often should commercial irrigation water be tested?

Establish a baseline before use; retest after changes in source or treatment and according to seasonal variability and crop risk. Use field meters more frequently for operations and periodically confirm chemistry through a laboratory.

Can recirculating irrigation water be reused indefinitely?

Do not assume so. Individual-ion changes, dissolved salts, biological concerns and system performance can make periodic treatment or replacement necessary. Water reuse needs a monitored facility-specific operating plan.

Research and Extension References

These references support the article's science and management framework. Numerical guidance in any source must be interpreted within its crop, climate, and production-system scope.

  1. Oregon State University Extension Service. Irrigation and Water Quality. Peer-reviewed regional technical guidance; sampling, source-water salts, runoff, and ion interpretation.
  2. Penn State Extension. Interpreting Irrigation Water Tests (updated 2025). Irrigation-water panels, alkalinity versus pH, and greenhouse interpretation limitations.
  3. Penn State Extension. A Water Quality Toolkit for Greenhouse and Nursery Production (updated 2025). Field measurement and monitoring of pH, alkalinity, hardness and EC.
  4. Oklahoma State University Extension. Understanding Your Irrigation Water Test Report. Ionic hazards, EC, SAR, salinity and crop/soil context.
  5. University of Georgia Cooperative Extension. Fertilizer Injectors: Selection, Maintenance and Calibration. Commercial injectors, stock tanks and validation of delivery.
  6. Penn State Extension. Hydroponics Systems: Nutrient Solution Programs and Recipes (2024). Fertilizer-stock solubility and compatibility.
  7. Fathidarehnijeh, E., et al. (2023/2024). Current perspective on nutrient solution management strategies to improve the nutrient and water use efficiency in hydroponic systems. Canadian Journal of Plant Science, 104(2), 88–102. DOI: 10.1139/cjps-2023-0034.
  8. Houston, L. L., Dickson, R. W., Bertucci, M. B., and Roberts, T. L. (2023). Evaluating species-specific replenishment solution effects on plant growth and root-zone nutrients with hydroponic arugula and basil. Horticulturae, 9(4), 486. DOI: 10.3390/horticulturae9040486.
  9. Langenfeld, N. J. and Bugbee, B. (2024). Sustainable Hydroponics Using Zero-discharge Nutrient Management and Automated pH Control. HortScience, 59(8), 1202–1206. DOI: 10.21273/HORTSCI17975-24.
  10. U.S. Environmental Protection Agency. Consumer Confidence Reports for community water systems. Context and limitations for municipal drinking-water reports.
  11. Centers for Disease Control and Prevention. Guidelines for Testing Well Water. Private-well drinking-water guidance, distinct from agronomic testing.

Editorial note: this article provides general commercial agronomy education, not a universal fertilizer recipe, precise acid-dosing instruction, drinking-water safety determination, or pesticide/sanitizer application direction. Crop targets and product directions require verified crop, water, equipment and label information.

Back to blog

1 comment

I used the well water from my tap to water and now I’m getting curling tips on new growth leaves and burnt edges on slightly older leaves. Biggest leaves are ok but now I’ll be using spring water and may do a flush here soon.

Joe,

Leave a comment

Please note, comments need to be approved before they are published.